NDSU Greenhouse Studies Yield More Tips for
Improved Fungicide Spraying
for Wheat/Barley Head Scab Control
Extension Report 56, June 1999
Marcia McMullen, Scott Halley, Jeremy Pederson, Vern Hofman,
Jim Moos, Suranjin Panigrahi, Dan Gu, Terry Gregoire
Introduction
A new semi-permanent greenhouse was built on the NDSU campus in the fall of 1998 for
the purpose of learning more about optimizing spray techniques to improve fungicide
application and control of head scab of wheat, durum and barley. The greenhouse structure
was funded through federal dollars obtained, in part, with the aid of regional wheat and
barley groups. The materials, supplies and labor for operating the greenhouse were funded
by North Dakota and Minnesota wheat and barley commodity groups, private agricultural crop
protection companies, the NDSU Research Foundation and the North Dakota State Board of
Agriculture Research.
Previous studies among a team of researchers in North Dakota indicated that fungicide
treatments were most effective if sprays were directed at an angle more perpendicular
toward the wheat and barley heads, rather than directed straight down. Also, previous work
had indicated that the flowering stage was the optimum time to apply fungicides to wheat,
and efficacies of available fungicides had been evaluated. Additional work was needed on
understanding optimum spray nozzles, sprayer pressures, gallons per acre (gpa), adjuvant
effects, and timing of application for barley.
Methods
Russ hard red spring wheat, Robust barley, and Munich durum were seeded in the
greenhouse and were in the full heading stage by the end of February. Over 40 different
trials were done on these headed plants to evaluate percent head coverage with the spray
and disease control with fungicides. Sprays were applied with a track sprayer designed by
Agricultural and Biosystems Engineering personnel.
Percent head coverage was measured using an indicator orange day glo dye and a digital
analysis system, also designed by Agricultural and Biosystems Engineering. In addition,
fungicides were applied in some trials to determine efficacy against head scab, following
inoculation and misting of plants to create a growth environment conducive for scab.
Spray Variables Studied
The following spray parameters were evaluated:
- Spray pressure: 30 psi to 90 psi in 10 psi increments.
- Spray nozzles: XR8001 flat fans oriented forward and backward in a double swivel body;
TD01 turbo drop nozzles oriented forward and backward in a double swivel body; TwinJet
TJ8002 nozzles oriented vertically; experimental Air Assist oriented vertically, and a
dual set oriented forward/backward.
- Gallons of water per acre (gpa); 9 to 54 gpa.
- Growth stage of barley at inoculation and at time of fungicide application.
- Adjuvants
General Conclusions
Optimum conditions varied across crops as well as with nozzle type. For each small
grain, the following was found:
Hard red spring wheat Although the TwinJet TJ8002
nozzle costs less than the forward/backward arrangements, this nozzle generally provided
less head coverage as compared to the forward/backward orientations of the XR8001 flat
fans or the forward/backward oriented TD01s (Figure 1). For the XR8001 nozzles, the best
coverage occurred at 30-40 psi, or at 80-90 psi at 18 gpa, and lowest head coverage
occurred at 50-60 psi at 9 gpa. TD01 nozzles performed optimally at 60 psi at 18 gpa in
these tests.
Figure 1. Effect of pressure and gpa on head coverage of Russ HRSW with
forward/backward XR8001 or TD01 nozzles, and vertical TJ8002 nozzles.

Durum wheat Increased water volume improved head
coverage of both the XR8001 and the TD01 nozzles on Munich durum (Figure 2). The XR8001
with 18gpa at 40 psi provided the best percent head coverage in this trial.
Figure 2. Effect of pressure and gallonage on coverage of heads of Munich durum
with forward/backward XR8001 and forward/backward oriented TD01 nozzles.

For Munich durum, increased water volume was essential for improved head coverage and
disease control (Figure 3). Head coverage increased steadily with increased gpa, but
disease severity decreased only up to the 36 gpa volume.
Figure 3. Comparison of coverage data to scab head severity with Folicur applied
to Munich durum with forward/backward XR8001 nozzle at 90 psi at various gpa.

Barley The percent head coverage on barley was
consistently better with the forward/backward XR8001 flat fans than the forward/backward
TD01 nozzles at both 9 and 18 gpa and across psi's, with 30-40 psi giving the best
coverage (Figure 4). Increased gpa also improved head coverage, but in an inoculation
experiment, increased gpa only slightly reduced disease severity.
Figure 4. Effect of pressure and gallonage on coverage of heads of Robust barley
with forward/backward oriented XR8001 & TD01 nozzles.

Treatment timing on barley A timing-of-inoculation
study showed that head scab did not develop substantially when barley was inoculated when
awns were just showing but became severe when fully emerged heads were inoculated (Figure
5). Fungicide application also was more effective when the fungicide was applied before
inoculation than after inoculation. These results indicate that application of a fungicide
should be in early head emergence or very soon after head emergence, when environment is
favorable for the disease.
Figure 5. Head severity of scab in barley when crop inoculated at different
growth stages.

Adjuvants Tests with Folicur and Tilt fungicides
indicated that the addition of an appropriate adjuvant generally increased head coverage
and disease control.
Other comments An experimental air-assist was built
to be used in the greenhouse. Some initial experiments indicated that a downward
orientation did not provide as much coverage as compared to a dual air assist system
mounted both forward and backward toward the grain heads. A diagram of this experimental
forward/backward mounted dual assist sprayer is provided in Figure 6. More work is planned
during the growing season with this experimental air assist mounted to a tractor sprayer.
Figure 6. Experimental dual air assist configuration.

Summer Research Some new experimental fungicides will
be evaluated this summer for control of head scab and leaf diseases of wheat, durum, and
barley. In addition, refinement of application pressures and gpa will be studied, and
further study on air-assist spraying will occur at Fargo and Langdon. Several trials with
aerial application at different spray volumes are planned as well.
Summary Recommendations
- Angle spray towards grain head using forward and backward mounted nozzles
- Use 40 psi for XR flat fan tips or 80-90 psi with 18 gpa; If use Turbo TD01 nozzles,
need higher pressures (60 psi)
- Increase spray volume to improve head coverage
- Spray hard red spring wheat and durum at early flowering (Feekes 10.51)
- Spray barley at early heading (Feekes 10.3-10.5)
- Use appropriate adjuvant for fungicide used
- When using ground equipment, spray in evening, prior to heavy night dews
- When using aerial application, spray in evening or early morning, when dew present, and
increase water volume (7.5 gpa as compared to 5 gpa)
Extension Report 56, June 1999
|